Power Transformer: 110V and 220V input, with two 15V outputs 180 degrees out of phase










6














I have never designed a power supply before and have a few questions and would appreciate any help.



  • Firstly, I want to use a transformer that can both take 220V and 110V inputs. Can I use a center tap transformer and for 110V put the coils in series and for 220V only use one coil and leave the second open circuited?


  • Secondly, I need an output of + and - 15, so do I select a transformer with a center tap secondary and wire the two identical outputs to be 180 degrees out of phase?


  • Lastly, I cannot find any transformers with these specifications. What I've been looking for is a center tap primary and secondary with a ratio of 15:1


Thank you in advance.










share|improve this question



















  • 1




    Is that 15V AC or DC? And does it need to be isolated?
    – ratchet freak
    Nov 12 at 12:08







  • 1




    A centre tapped transformer CANNOT be rewired as you seem to be implying.
    – Andy aka
    Nov 12 at 12:34















6














I have never designed a power supply before and have a few questions and would appreciate any help.



  • Firstly, I want to use a transformer that can both take 220V and 110V inputs. Can I use a center tap transformer and for 110V put the coils in series and for 220V only use one coil and leave the second open circuited?


  • Secondly, I need an output of + and - 15, so do I select a transformer with a center tap secondary and wire the two identical outputs to be 180 degrees out of phase?


  • Lastly, I cannot find any transformers with these specifications. What I've been looking for is a center tap primary and secondary with a ratio of 15:1


Thank you in advance.










share|improve this question



















  • 1




    Is that 15V AC or DC? And does it need to be isolated?
    – ratchet freak
    Nov 12 at 12:08







  • 1




    A centre tapped transformer CANNOT be rewired as you seem to be implying.
    – Andy aka
    Nov 12 at 12:34













6












6








6







I have never designed a power supply before and have a few questions and would appreciate any help.



  • Firstly, I want to use a transformer that can both take 220V and 110V inputs. Can I use a center tap transformer and for 110V put the coils in series and for 220V only use one coil and leave the second open circuited?


  • Secondly, I need an output of + and - 15, so do I select a transformer with a center tap secondary and wire the two identical outputs to be 180 degrees out of phase?


  • Lastly, I cannot find any transformers with these specifications. What I've been looking for is a center tap primary and secondary with a ratio of 15:1


Thank you in advance.










share|improve this question















I have never designed a power supply before and have a few questions and would appreciate any help.



  • Firstly, I want to use a transformer that can both take 220V and 110V inputs. Can I use a center tap transformer and for 110V put the coils in series and for 220V only use one coil and leave the second open circuited?


  • Secondly, I need an output of + and - 15, so do I select a transformer with a center tap secondary and wire the two identical outputs to be 180 degrees out of phase?


  • Lastly, I cannot find any transformers with these specifications. What I've been looking for is a center tap primary and secondary with a ratio of 15:1


Thank you in advance.







power transformer






share|improve this question















share|improve this question













share|improve this question




share|improve this question








edited Nov 12 at 12:50









SamGibson

10.8k41537




10.8k41537










asked Nov 12 at 12:05









Andre Faraday

364




364







  • 1




    Is that 15V AC or DC? And does it need to be isolated?
    – ratchet freak
    Nov 12 at 12:08







  • 1




    A centre tapped transformer CANNOT be rewired as you seem to be implying.
    – Andy aka
    Nov 12 at 12:34












  • 1




    Is that 15V AC or DC? And does it need to be isolated?
    – ratchet freak
    Nov 12 at 12:08







  • 1




    A centre tapped transformer CANNOT be rewired as you seem to be implying.
    – Andy aka
    Nov 12 at 12:34







1




1




Is that 15V AC or DC? And does it need to be isolated?
– ratchet freak
Nov 12 at 12:08





Is that 15V AC or DC? And does it need to be isolated?
– ratchet freak
Nov 12 at 12:08





1




1




A centre tapped transformer CANNOT be rewired as you seem to be implying.
– Andy aka
Nov 12 at 12:34




A centre tapped transformer CANNOT be rewired as you seem to be implying.
– Andy aka
Nov 12 at 12:34










2 Answers
2






active

oldest

votes


















8














Using a centre-tapped primary usually means that you de-rate the transformer to half power.



enter image description here



Figure 1. Series and parallel connections for split-winding transformer. Image source: Electro-Dan. The linked article discusses torroidal transformers but the principle is the same for standard transformers.



Instead, the common approach due to its flexibility is to use a transformer with two 110 V primaries and two equal secondaries. The primaries can then be wired in series for 220 V operation and parallel for 110 V. Similarly, the secondaries can be wired in parallel for high current or series for higher voltage. The series connection point is, in effect, the secondary centre-tap.



enter image description here



Figure 2. For switching primary voltage by the user you would add a voltage selector switch. Source: Modulus Amplification.






share|improve this answer




















  • Thank you very much! Helped a lot!
    – Andre Faraday
    Nov 12 at 14:16










  • The yellow and blue is not a center tap, they are the ends of two windings. A center tap is continuous through the transformer and cannot be separated.
    – Harper
    Nov 12 at 19:20


















6















Firstly, I want to use a transformer that can both take 220V and 110V inputs. Can I use a center tap transformer and for 110V put the coils in series and for 220V only use one coil and leave the second open circuited?




The normal approach is to use a transformer that has two identical primary windings, each rated for 110V and half the total transformer power. You put them in parallel for 110V operation and put them in series for 220V operation. This optimizes the amount of copper required.




Secondly, I need an output of + and - 15, so do I select a transformer with a center tap secondary and wire the two identical outputs to be 180 degrees out of phase?




If you ground the center tap, you can use the other two terminals to make separate +15V and -15V supplies. The fact that they are out of phase allows you to use full-wave rectification for both supplies.




Lastly, I cannot find any transformers with these specifications.




That would be a product recommendation, which is off-topic here.






share|improve this answer




















  • Yeah, and don't attempt to half-wave rectify them unless either your load is balanced or your transformer mount is very sturdy and well dampened :)
    – rackandboneman
    Nov 12 at 19:43










Your Answer





StackExchange.ifUsing("editor", function ()
return StackExchange.using("mathjaxEditing", function ()
StackExchange.MarkdownEditor.creationCallbacks.add(function (editor, postfix)
StackExchange.mathjaxEditing.prepareWmdForMathJax(editor, postfix, [["\$", "\$"]]);
);
);
, "mathjax-editing");

StackExchange.ifUsing("editor", function ()
return StackExchange.using("schematics", function ()
StackExchange.schematics.init();
);
, "cicuitlab");

StackExchange.ready(function()
var channelOptions =
tags: "".split(" "),
id: "135"
;
initTagRenderer("".split(" "), "".split(" "), channelOptions);

StackExchange.using("externalEditor", function()
// Have to fire editor after snippets, if snippets enabled
if (StackExchange.settings.snippets.snippetsEnabled)
StackExchange.using("snippets", function()
createEditor();
);

else
createEditor();

);

function createEditor()
StackExchange.prepareEditor(
heartbeatType: 'answer',
autoActivateHeartbeat: false,
convertImagesToLinks: false,
noModals: true,
showLowRepImageUploadWarning: true,
reputationToPostImages: null,
bindNavPrevention: true,
postfix: "",
imageUploader:
brandingHtml: "Powered by u003ca class="icon-imgur-white" href="https://imgur.com/"u003eu003c/au003e",
contentPolicyHtml: "User contributions licensed under u003ca href="https://creativecommons.org/licenses/by-sa/3.0/"u003ecc by-sa 3.0 with attribution requiredu003c/au003e u003ca href="https://stackoverflow.com/legal/content-policy"u003e(content policy)u003c/au003e",
allowUrls: true
,
onDemand: true,
discardSelector: ".discard-answer"
,immediatelyShowMarkdownHelp:true
);



);













draft saved

draft discarded


















StackExchange.ready(
function ()
StackExchange.openid.initPostLogin('.new-post-login', 'https%3a%2f%2felectronics.stackexchange.com%2fquestions%2f406324%2fpower-transformer-110v-and-220v-input-with-two-15v-outputs-180-degrees-out-of%23new-answer', 'question_page');

);

Post as a guest















Required, but never shown

























2 Answers
2






active

oldest

votes








2 Answers
2






active

oldest

votes









active

oldest

votes






active

oldest

votes









8














Using a centre-tapped primary usually means that you de-rate the transformer to half power.



enter image description here



Figure 1. Series and parallel connections for split-winding transformer. Image source: Electro-Dan. The linked article discusses torroidal transformers but the principle is the same for standard transformers.



Instead, the common approach due to its flexibility is to use a transformer with two 110 V primaries and two equal secondaries. The primaries can then be wired in series for 220 V operation and parallel for 110 V. Similarly, the secondaries can be wired in parallel for high current or series for higher voltage. The series connection point is, in effect, the secondary centre-tap.



enter image description here



Figure 2. For switching primary voltage by the user you would add a voltage selector switch. Source: Modulus Amplification.






share|improve this answer




















  • Thank you very much! Helped a lot!
    – Andre Faraday
    Nov 12 at 14:16










  • The yellow and blue is not a center tap, they are the ends of two windings. A center tap is continuous through the transformer and cannot be separated.
    – Harper
    Nov 12 at 19:20















8














Using a centre-tapped primary usually means that you de-rate the transformer to half power.



enter image description here



Figure 1. Series and parallel connections for split-winding transformer. Image source: Electro-Dan. The linked article discusses torroidal transformers but the principle is the same for standard transformers.



Instead, the common approach due to its flexibility is to use a transformer with two 110 V primaries and two equal secondaries. The primaries can then be wired in series for 220 V operation and parallel for 110 V. Similarly, the secondaries can be wired in parallel for high current or series for higher voltage. The series connection point is, in effect, the secondary centre-tap.



enter image description here



Figure 2. For switching primary voltage by the user you would add a voltage selector switch. Source: Modulus Amplification.






share|improve this answer




















  • Thank you very much! Helped a lot!
    – Andre Faraday
    Nov 12 at 14:16










  • The yellow and blue is not a center tap, they are the ends of two windings. A center tap is continuous through the transformer and cannot be separated.
    – Harper
    Nov 12 at 19:20













8












8








8






Using a centre-tapped primary usually means that you de-rate the transformer to half power.



enter image description here



Figure 1. Series and parallel connections for split-winding transformer. Image source: Electro-Dan. The linked article discusses torroidal transformers but the principle is the same for standard transformers.



Instead, the common approach due to its flexibility is to use a transformer with two 110 V primaries and two equal secondaries. The primaries can then be wired in series for 220 V operation and parallel for 110 V. Similarly, the secondaries can be wired in parallel for high current or series for higher voltage. The series connection point is, in effect, the secondary centre-tap.



enter image description here



Figure 2. For switching primary voltage by the user you would add a voltage selector switch. Source: Modulus Amplification.






share|improve this answer












Using a centre-tapped primary usually means that you de-rate the transformer to half power.



enter image description here



Figure 1. Series and parallel connections for split-winding transformer. Image source: Electro-Dan. The linked article discusses torroidal transformers but the principle is the same for standard transformers.



Instead, the common approach due to its flexibility is to use a transformer with two 110 V primaries and two equal secondaries. The primaries can then be wired in series for 220 V operation and parallel for 110 V. Similarly, the secondaries can be wired in parallel for high current or series for higher voltage. The series connection point is, in effect, the secondary centre-tap.



enter image description here



Figure 2. For switching primary voltage by the user you would add a voltage selector switch. Source: Modulus Amplification.







share|improve this answer












share|improve this answer



share|improve this answer










answered Nov 12 at 12:33









Transistor

80.2k778173




80.2k778173











  • Thank you very much! Helped a lot!
    – Andre Faraday
    Nov 12 at 14:16










  • The yellow and blue is not a center tap, they are the ends of two windings. A center tap is continuous through the transformer and cannot be separated.
    – Harper
    Nov 12 at 19:20
















  • Thank you very much! Helped a lot!
    – Andre Faraday
    Nov 12 at 14:16










  • The yellow and blue is not a center tap, they are the ends of two windings. A center tap is continuous through the transformer and cannot be separated.
    – Harper
    Nov 12 at 19:20















Thank you very much! Helped a lot!
– Andre Faraday
Nov 12 at 14:16




Thank you very much! Helped a lot!
– Andre Faraday
Nov 12 at 14:16












The yellow and blue is not a center tap, they are the ends of two windings. A center tap is continuous through the transformer and cannot be separated.
– Harper
Nov 12 at 19:20




The yellow and blue is not a center tap, they are the ends of two windings. A center tap is continuous through the transformer and cannot be separated.
– Harper
Nov 12 at 19:20













6















Firstly, I want to use a transformer that can both take 220V and 110V inputs. Can I use a center tap transformer and for 110V put the coils in series and for 220V only use one coil and leave the second open circuited?




The normal approach is to use a transformer that has two identical primary windings, each rated for 110V and half the total transformer power. You put them in parallel for 110V operation and put them in series for 220V operation. This optimizes the amount of copper required.




Secondly, I need an output of + and - 15, so do I select a transformer with a center tap secondary and wire the two identical outputs to be 180 degrees out of phase?




If you ground the center tap, you can use the other two terminals to make separate +15V and -15V supplies. The fact that they are out of phase allows you to use full-wave rectification for both supplies.




Lastly, I cannot find any transformers with these specifications.




That would be a product recommendation, which is off-topic here.






share|improve this answer




















  • Yeah, and don't attempt to half-wave rectify them unless either your load is balanced or your transformer mount is very sturdy and well dampened :)
    – rackandboneman
    Nov 12 at 19:43















6















Firstly, I want to use a transformer that can both take 220V and 110V inputs. Can I use a center tap transformer and for 110V put the coils in series and for 220V only use one coil and leave the second open circuited?




The normal approach is to use a transformer that has two identical primary windings, each rated for 110V and half the total transformer power. You put them in parallel for 110V operation and put them in series for 220V operation. This optimizes the amount of copper required.




Secondly, I need an output of + and - 15, so do I select a transformer with a center tap secondary and wire the two identical outputs to be 180 degrees out of phase?




If you ground the center tap, you can use the other two terminals to make separate +15V and -15V supplies. The fact that they are out of phase allows you to use full-wave rectification for both supplies.




Lastly, I cannot find any transformers with these specifications.




That would be a product recommendation, which is off-topic here.






share|improve this answer




















  • Yeah, and don't attempt to half-wave rectify them unless either your load is balanced or your transformer mount is very sturdy and well dampened :)
    – rackandboneman
    Nov 12 at 19:43













6












6








6







Firstly, I want to use a transformer that can both take 220V and 110V inputs. Can I use a center tap transformer and for 110V put the coils in series and for 220V only use one coil and leave the second open circuited?




The normal approach is to use a transformer that has two identical primary windings, each rated for 110V and half the total transformer power. You put them in parallel for 110V operation and put them in series for 220V operation. This optimizes the amount of copper required.




Secondly, I need an output of + and - 15, so do I select a transformer with a center tap secondary and wire the two identical outputs to be 180 degrees out of phase?




If you ground the center tap, you can use the other two terminals to make separate +15V and -15V supplies. The fact that they are out of phase allows you to use full-wave rectification for both supplies.




Lastly, I cannot find any transformers with these specifications.




That would be a product recommendation, which is off-topic here.






share|improve this answer













Firstly, I want to use a transformer that can both take 220V and 110V inputs. Can I use a center tap transformer and for 110V put the coils in series and for 220V only use one coil and leave the second open circuited?




The normal approach is to use a transformer that has two identical primary windings, each rated for 110V and half the total transformer power. You put them in parallel for 110V operation and put them in series for 220V operation. This optimizes the amount of copper required.




Secondly, I need an output of + and - 15, so do I select a transformer with a center tap secondary and wire the two identical outputs to be 180 degrees out of phase?




If you ground the center tap, you can use the other two terminals to make separate +15V and -15V supplies. The fact that they are out of phase allows you to use full-wave rectification for both supplies.




Lastly, I cannot find any transformers with these specifications.




That would be a product recommendation, which is off-topic here.







share|improve this answer












share|improve this answer



share|improve this answer










answered Nov 12 at 12:34









Dave Tweed

117k9144256




117k9144256











  • Yeah, and don't attempt to half-wave rectify them unless either your load is balanced or your transformer mount is very sturdy and well dampened :)
    – rackandboneman
    Nov 12 at 19:43
















  • Yeah, and don't attempt to half-wave rectify them unless either your load is balanced or your transformer mount is very sturdy and well dampened :)
    – rackandboneman
    Nov 12 at 19:43















Yeah, and don't attempt to half-wave rectify them unless either your load is balanced or your transformer mount is very sturdy and well dampened :)
– rackandboneman
Nov 12 at 19:43




Yeah, and don't attempt to half-wave rectify them unless either your load is balanced or your transformer mount is very sturdy and well dampened :)
– rackandboneman
Nov 12 at 19:43

















draft saved

draft discarded
















































Thanks for contributing an answer to Electrical Engineering Stack Exchange!


  • Please be sure to answer the question. Provide details and share your research!

But avoid


  • Asking for help, clarification, or responding to other answers.

  • Making statements based on opinion; back them up with references or personal experience.

Use MathJax to format equations. MathJax reference.


To learn more, see our tips on writing great answers.





Some of your past answers have not been well-received, and you're in danger of being blocked from answering.


Please pay close attention to the following guidance:


  • Please be sure to answer the question. Provide details and share your research!

But avoid


  • Asking for help, clarification, or responding to other answers.

  • Making statements based on opinion; back them up with references or personal experience.

To learn more, see our tips on writing great answers.




draft saved


draft discarded














StackExchange.ready(
function ()
StackExchange.openid.initPostLogin('.new-post-login', 'https%3a%2f%2felectronics.stackexchange.com%2fquestions%2f406324%2fpower-transformer-110v-and-220v-input-with-two-15v-outputs-180-degrees-out-of%23new-answer', 'question_page');

);

Post as a guest















Required, but never shown





















































Required, but never shown














Required, but never shown












Required, but never shown







Required, but never shown

































Required, but never shown














Required, but never shown












Required, but never shown







Required, but never shown







這個網誌中的熱門文章

What does pagestruct do in Eviews?

Dutch intervention in Lombok and Karangasem

Channel Islands